221
Manual # 016-0159-894 Rev H 01/07
7 - Using AutoBoom
Autoboom uses default settings for sensor height, sensitivity and speed.
Normally, these values will work for your machine. The default setting for
the Sensitivity is 15 and the Speed is 25. If the booms start to oscillate or
act otherwise unstable, this is an indication that either the Speed or the
Sensitivity is set too high. Reducing the set point for either should improve
performance. Once the Speed and Sensitivity are set, only minor adjust-
ments are required to account for changing field conditions. The height of
the boom above the ground can also be adjusted by setting the height of
the ultrasonic sensor over the ground.
To adjust the Speed, Sensitivity, and/or Sensor Height settings of Autoboom,
press in the center portion of the Autoboom area on the Viper main menu
screen. The following screen will display.
To Adjust Sensor Height:
1. Press the up arrow in the Sensor Height area of the Autoboom
Control screen to increase the distance of the ultrasonic sensor
and the ground.
2. Press the down arrow in the Sensor Height area of the Autoboom
Control screen to decrease the distance of the ultrasonic sensor
and the ground.
To Adjust Sensitivity:
1. Press the up arrow in the Sensitivity area of the Autoboom
Control screen to increase the sensitivity of the boom response.
2. Press the down arrow in the Sensitivity area of the Autoboom
Control screen to decrease the sensitivity of the boom response.
UltraGlide
System
Adjustment
Kommentare zu diesen Handbüchern