Viper 3606V Bedienerhandbuch Seite 19

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 33
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 18
16
© 2013 Directed. All rights reserved.
Alarm Features
Normal Arm Protection
Status LED: The Control Center Status LED flashes as a visual indicator
that your vehicle’s security system is active.
Starter Kill: The Failsafe starter kill relay prevents the engine from
starting
Note
May require additional parts and installation
Sensor triggers: The shock sensor can distinguish minor impacts from
major impacts to the vehicle exterior. Minor impacts causes the system
to emit a Warn-away output. Major impacts caused for example by a
forcible entry attempt, results in a Full Trigger output.
Point of entry triggers: Opening the hood or trunk causes a Full Trig-
ger output, while opening a Door or turning on the Ignition causes
the the siren to chirp three seconds before beginning the Full Trigger
output. This three second delay allows time to disarm and silence the
siren in case of accidental trigger.
Sensor Silent Arm protection
Sensor Warn-away and Sensor Full Trigger activations are defeated.
Point of entry triggers will activate the Full Trigger output.
Full Silent Arm Protection
Sensor Warn-away, Sensor Full Trigger and Point of Entry activations
are defeated. Only the Ignition input will activate the Full Trigger out-
put.
Seitenansicht 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 32 33

Kommentare zu diesen Handbüchern

Keine Kommentare