ttaabbllee ooff zzoonneess
When using the Diagnostic functions, use the Table of Zones to see which input has triggered the system. It is
also helpful in deciding which input to use when connecting optional sensors and switches.
ttrroouubblleesshhoooottiinngg
DDoooorr iinnppuutt ddooeess nnoott iimmmmeeddiiaatteellyy ttrriiggggeerr ffuullll aallaarrmm.. IInnsstteeaadd,, ffiirrsstt II hheeaarr cchhiirrppss ffoorr 33 sseeccoonnddss::
That's how the progressive two-stage door input works! This is a feature of this system. This is an instant trigger,
remember, since even if the door is instantly re-closed, the progression from chirps to constant siren will con-
tinue.
C
Clloossiinngg tthhee ddoooorr ttrriiggggeerrss tthhee ssyysstteemm,, bbuutt ooppeenniinngg tthhee ddoooorr ddooeess nnoott::
Have you correctly identified the type of door switch system? This often happens when the wrong door input has
been used. (See
H1/5 GREEN Door Trigger Input, Primary Harness Wire Connection Guide
section of this guide.)
SSyysstteemm wwiillll nnoott ppaassssiivveellyy aarrmm uunnttiill iitt iiss rreemmootteellyy aarrmmeedd aanndd tthheenn ddiissaarrmmeedd::
Are the door inputs connected? Is the H1/6 blue wire connected to the door trigger wire in the vehicle? Either
the H1/5 green or the H1/7 violet should be used instead. (See
Primary Harness Wire Connection Guide
section
of this guide.)
ZZOONNEE NNOO.. TTRRIIGGGGEERR TTYYPPEE IINNPPUUTT DDEESSCCRRIIPPTTIIOONN
1 Multiplex H1/6 BLUE wire. Connects to optional hood/trunk pins or
an optional sensor. Inputs longer than 0.8 seconds will
instantly trigger the full alarm sequence and report Zone 1.
2 On-board impact sensor Second-stage of on-board impact sensor (heavy impacts
from impact sensor).
3 Two-stage, progresses from Door switch circuit. H1/5 GREEN or H1/7 VIOLET.
warning to full alarm
5 Two-stage, progresses from Ignition. H1/9 YELLOW.
warning to full alarm
NNOOTTEE
: The Warn-away response does not report on the LED.